Dayman Technical Build Chemicals

Phone : + 90 224 452 55 16

Email : info@dayman.com.tr

RESIN BASED WATERPROOFING PRODUCTS

BITUMEPOL – 812

Two component, polyurethane based, bitumen containing fast curing, elastic, cold
applied liquid membrane.

Description

Two component, polyurethane based,
bitumen containing fast curing, elastic, cold
applied liquid membrane.
It adheres perfectly to almost any surface to
which it is applied, forming a high elastic
film.
It is chemically cured to form an elastic and
durable film.

DESCRIPTION:
Two component, polyurethane based,
bitumen containing fast curing, elastic, cold
applied liquid membrane.
It adheres perfectly to almost any surface to
which it is applied, forming a high elastic
film.
It is chemically cured to form an elastic and
durable film.

ADVANTAGES:
Easy preparation (brush, roll or with airless
spray).
When applied, it forms a one-piece
waterproofing layer that does not cause
seams or leaks,high stretching,
Very high elasticity
Fast curing
Excellent mechanical properties, high
elongation, tensile, tear and abrasion
resistance.
Stable water and frost resistant.
Heat resistance performance in wide
temperature range, it is between -40 °C and
+ 90 °C.
Even if the waterproofing layer is damaged
in any way the damaged part can be easily
repaired in a short time,
Can be used as a joint material.
Resistant to chemicals.

USAGE AREAS:
Water tank (excluding drinkable water
stock),
Floors,
Grounds,
Bridge platforms,
Open-close tunnels,
Can be applied in bath, terrace and in the
roofs under tiles.
Retaining Walls,
Plaster and cement panels,
EPDM membranes,
Asphalt membranes,
Green roofs and plant tars,
Lightweight roof (metal or fiber cement),
Car park.

( 23 °C Temparature and 50 % for relative
humidity)
Coating Type : Polyurethane – Bitümen
Color : Black
Density : 1,00 gr/cm3 ±0.02
Viscosity : 3000-3500 cp
Application Temperature : +5 C ile +35 C
Thinning : Not Suggested
Teoric Consume : 1,50-2,00 kg/m2
Pot Life : 20 C 30-35 minutes
Elasticity : > % 2000
Adhesion to Concrate : < 2,0 N/mm2
Break Resistance : >2,0 N/mm2
Application Metod: Roll,Brush,Spray
Dry Time: 1 hour
Coating Again: 8-24 hours
Complete Dry : 7 days
***These values were obtained as a result
of laboratory tests, just contain finished
applications according to drying time
performance. Due to differences in
temperature and humidity values in the
construction site, the values may change.

Surface Preparation:
The surface; must be cured, dry and
durable. Loose surface mortar and such as
residues should be cleaned and reached
durable surface.
The holes and gaps on the surface, should
be repaired with the repair mortar prepared
by mixing with DAYMAN PAIR PLUS and
DAYMAN EPO MORTAR or DAYMAN
EPO BOND.
Corner joints should be chamfered by series
of DAYMAN REPAIR PLUS with the size of
4×4.
Out corner joints should be broken first and
then chamfered.

Preparation Of The Mixture:
A and B component should be mixed by a
medium 400-600 rpm.mixer until having a
homogenous shape,
Application:
The surface should be primed with
AQUAPOL PR 800, AQUAPOL PR WT 801
or a suitable primer.
The application should be done by brush,
trowel or spray,
The ready mix should be used in 30
minutes,
The gelled mix should not be used,
On the primed surface, the bucket can be
immerse or poured, use brush or roll until
the surface completely covered, apply
minimum two layer,
Application temperature should be between
+5°C +30°C

If the weather is rainy or possible rainy days
the application should not be done,
After the application it must be protected
from strong wind, storm and sun in the first
24 hours,
The application should be made on the part
of the structure that comes into contact with
water.
As the product become slowly cured in the
cold weathers, the second coating must be
done when the first coating is completely
becoming dry.
Ensure that the ambient and floor
temperature is between 5 ° C and 30 ° C.

CLEANING OF INSTRUMENTS:
BİTUMEPOL – 812 should be cleaned by
solvent when it wet.
BİTUMEPOL – 812 after become dry should
be cleaned by the mechanical ways.

CONSUME:
Only for one layer, min.: 0,750-0, 1, 00
kg/m²
Total theoric consume (for two layer): 1, 50
– 2, 00 Kg/m²

PACKING:
15, 00 + 15,00 – 00 kg
80×120 pallet dimension
16 set / 36 bin on pallet

COLOR:
Black

SHELF LIFE:
Shelf life is 12 months.
Should be stored in the dry and cool are,
should be attended to not put under sun or
the area that takes direct sun and should be
protected from the frost.
Do not stack pallets on top of each other, it
should be shipped first in first out.

SAFETY RECOMMENDATIONS:
Wear work clothes, protective gloves,
glasses and masks should be used during
application.
Do not smoke during the application and
work in a well-ventilated place and away
from naked flames.
Hands and eyes should be protected by
protection equipment.
As cured materials has irritating effect, do
not touch with skin and eyes, in case of any
contact rinse with soap and plenty of water,
in case of any swallow see doctor urgently.
Food and beverage materials should not be
kept in the application area and should not
be eaten.
It should be known that the solvent is
heavier than air, so remember that it will be
on the ground.
Store out of reach of children.
For more information please check the
Material Safety Data Sheet.

LIMITATIONS OF LIABILITY:
The information in this technical data sheet
is given according to technical information,
experience and test result.
As GENERALTÜRK A.Ş. cannot control the
usage of the product that used under which
kind of conditions, it does not accept any
responsibility for the application result and
does not guarantee it.
The product suitability for the product user
should be tested and decided accordingly.
All products should be considered in the
advice of those technical knowledge and
equipment.
GENERAL TURK A.Ş can not accept any
resposibility that occures because of missuse,it only responsible for the written
suggestions that shows the products where
and how use.
GENERALTÜRK A.Ş. It may change the
properties of its products without
announcement.
The technical data sheet is valid until the
next time it is printed and all previous
technical data sheets invalidate the
description

Click to view the Technical Sheet.