Dayman Technical Build Chemicals

Phone : + 90 224 452 55 16

Email : info@dayman.com.tr

CERAMIC ADHESIVE AND JOINT FILLERS

CERABOND ACR – 916

It is a dispersion-based ceramic adhesive suitable for vertical and absorbent surfaces in
interior spaces

Description

It is a dispersion-based ceramic adhesive
suitable for vertical and absorbent surfaces
in interior spaces.

DESCRIPTION:
It is a dispersion-based ceramic adhesive
suitable for vertical and absorbent surfaces
in interior spaces.

ADVANTAGES:
It is ready to use.
It has high adherence.
It saves labor.
It is used in ceramic application over
ceramic.
Flexible.
It can be applied to the wooden surface,
thermal insulation board and plasterboard
etc.

USAGE AREAS:
Available use for ceramic, tile, glass mosaic,
marble and etc.
Indoor Applications:
Bath, WC, kitchen, wet areas.
Using on vertical applications.
It should not be used in outdoor horizontal
application that has continuous water
contact

( 23 °C Temparature and 50 % for relative
humidity)
Aderance : ≥ 1,0 N/mm²
Start : ≥ 1,0 N/mm²
After Immerse to Water : ≥ 1,0 N/mm²
After Heat Age : ≥ 1,0 N/mm²
After Freeze-Thaw : ≥ 1,0 N/mm²
Heating Resistane : (-40°C) – (+80°C)
Time for Joint Filler : 18 Hours
***These values were obtained as a result
of laboratory tests, just contain finished
applications according to drying time
performance. Due to differences in
temperature and humidity values in the
construction site, the values may change.

Surface Preparation:
The surface; must be cured, dry and
durable. Loose surface mortar and such as
residues should be cleaned and reached
durable surface.
In case of the necessity the surface should
cleaned mechanically.
Temperature should be between +10 °C
and +30 °C during the application.
Oil, grease, dirt, paint, salt and vomiting that
prevent adhesion should be removed.
If there are segregation, pits and fractures
on the surface, it should be repaired with
the repair mortar prepared by mixing with
DAYMAN REPAIR PLUS and DAYMAN
LATEX C, it should be applied at least 24
hour before,
The over ceramic applications should be
primed by DAYMAN ST PRIMER before the
application.

Preparation Of The Mixture:
The product is ready for use,
Should be mixed by 400 rpm until they
reach homogeneous consistency
As Adhesive:
CERA-BOND ACR 916 – joint trowel is
applied to the surface with hard rubber
tipped mop in 20 minutes.
The tiles should be placed on the adhesive
as leaving a joint gaps.
In order to get the best result from the
application, the tiles should be placed well
with the rubber hammer and the air should
be out.
Proper application for the thickness is 3
mm.

Temperature should be between +10 °C
and +30 °C during the application.
Do not apply on surfaces that are at risk of
frost.
In addition, it should not be applied in
extremely hot, rainy or windy weather.
These conditions can make shorter the
working time.
The expired or crusted mortar in the bucket
should not be used and should be disposed
of.
Wash the hands and used instruments with
plenty of the water after the application.
The surface that remained adhesive should
be cleaned by wet rag.
It should prevent from direct water contact
and pedestrian traffic in 24 hours.

CLEANING OF INSTRUMENTS:
DAYMAN CERA BOND –916 should be
cleaned by water when it wet.
DAYMAN CERA BOND – 916 after become
dry should be cleaned by the mechanical
ways.

CONSUME:
Various, 3,00-4,00 kg/m2.

PACKING:
15,00 kg. Bin
100×100 pallet dimension
36 qty.on pallet

COLOR:
White

SHELF LIFE:
1 year from the production date under
proper storage conditions.

SAFETY RECOMMENDATIONS:
Wear work clothes, protective gloves,
glasses and masks should be used during
application.
As it cement based, do not breath and do
not touch with skin and eyes,
Due to the irritating effects of the cured
materials, skin and eyes should not be
contacted, in case of contact with wash
plenty of water and soap, if swallowed seek
medical attention immediately.
Food and beverage materials should not be
kept in the application area and should not
be eaten.
Store out of reach of children.
This product packaging must be disposed of
in accordance with applicable laws.
This responsibility is belong the end user.
For more information please check the
Material Safety Data Sheet.

LIMITATIONS OF LIABILITY:
The information in this technical data sheet
is given according to technical information,
experience and test result.
As GENERALTÜRK A.Ş. cannot control the
usage of the product that used under which
kind of conditions, it does not accept any
responsibility for the application result and
does not guarantee it.
The product suitability for the product user
should be tested and decided accordingly.
All products should be considered in the
advice of those technical knowledge and
equipment.
GENERAL TURK A.Ş can not accept any
resposibility that occures because of missuse,it only responsible for the written
suggestions that shows the products where
and how use.
GENERALTÜRK A.Ş. It may change the
properties of its products without
announcement.
The technical data sheet is valid until the
next time it is printed and all previous
technical data sheets invalidate the
description

Click to view the Technical Sheet.