Dayman Technical Build Chemicals

Phone : + 90 224 452 55 16

Email : info@dayman.com.tr

THERMAL INSULATION SYSTEMS

D-THERM – 551

Cement based, polymer reinforced, one component heat insulation, containing special
chemical additives, board adhesive mortar.

Description

Cement based, polymer reinforced, one
component heat insulation, containing
special chemical additives, board adhesive
mortar.

DESCRIPTION:
Cement based, polymer reinforced, one
component heat insulation, containing
special chemical additives, board adhesive
mortar.

ADVANTAGES:
Excellent adhesion to mineral surfaces.
Easy to apply.
Water vapor permeable.
Resistant to freeze – thaw cycle.
Easy to prepare.
Working time is long.

USAGE AREAS:
Indoor and outdoor areas.
As an adhesive in jacketing manufacturing.
It is used as surface repair mortar on all
mineral surfaces.

((23°C, %50 Relative Humudity)
Dry Bulk Density :1350 ± 200 kg/m3
Compressive Strength 28 days: ≥ 6,00
N/mm2
Bending Strength 28 days :≥ 2,00 N/mm2
Total Curing Time : 28 Days
Temperature Strength :-20 °C +80°C
Application Temperature :+5°C +30°C
Color : Grey
***These values were obtained as a result
of laboratory tests, just contain finished
applications according to drying time
performance. Due to differences in
temperature and humidity values in the
construction site, the values may change.

Surface Preparation:
The surface; must be cured, dry and
durable. Loose surface mortar and such as
residues should be cleaned and reached
durable surface.
In case of the necessity the surface should
cleaned mechanically
Oil, grease, dirt, paint, salt and vomiting that
prevent adhesion should be removed.
The surface should be moist before the
application.

Preparation Of The Mixture:
6, 5 liter water is poured into an empty and
clean bucket, pour slowly D-THERM 551
into the water bucket and use 400 rpm
mixer until eliminate chunks of the powders.
Rest 5 minutes to have the mortar.
Before starting the application mix 30
second again.

Application:
The ready mixture is applied with a notched
trowel to all of the heating insulation sheet.
It is applied as a strip to the edges of the
sheet and as spots in the middle with mortar
trowel.
The mortar should touch at least 40% of the
boards.
During mortar application, the mortar on the
board should not be allowed to dry and form
a film layer. In such cases, the mortar
should be removed from the surface and a
new one applied.
The prepared mixture should be used within
1 hour.

Temperature should be between +5 °C and
+35 °C during the application.
Do not apply on surfaces that are at risk of
frost.
In addition, it should not be applied in
extremely hot, rainy or windy weather.
Drilling should not be performed until the
mortar is fully set. It should be known that
vibration and movement is given a negative
effect the integrity of the mortar.
The product should be protected from rain,
water, frost and negative external factors
until curing.

CLEANING OF INSTRUMENTS:
DAYMAN D-THERM 551 should be cleaned
by water when it wet.
DAYMAN D-THERM 551 after become dry
should be cleaned by the mechanical ways.

CONSUME:
Various 4, 00-6, 00 kg/m².

PACKING:
25, 00 in a craft bag (on the pallet 64).

COLOR:
Grey

SHELF LIFE:
1 year from the production date under
proper storage conditions.
Close tight the opened bags.

LIMITATIONS OF LIABILITY:
The information in this technical data sheet
is given according to technical information,
experience and test result.
As GENERALTÜRK A.Ş. cannot control the
usage of the product that used under which
kind of conditions, it does not accept any
responsibility for the application result and
does not guarantee it.
The product suitability for the product user
should be tested and decided accordingly.
All products should be considered in the
advice of those technical knowledge and
equipment.
GENERAL TURK A.Ş can not accept any
resposibility that occures because of missuse,it only responsible for the written
suggestions that shows the products where
and how use.
GENERALTÜRK A.Ş. It may change the
properties of its products without
announcement.
The technical data sheet is valid until the
next time it is printed and all previous
technical data sheets invalidate the
description

Click to view the Technical Sheet.