Dayman Technical Build Chemicals

Phone : + 90 224 452 55 16

Email : info@dayman.com.tr

MINERAL BASED WATERPROOFING PRODUCTS

D-LASTIC SUPER – 430

Cement based, added polymer emulsion, contains special chemicals, two component
waterproofing product.

Description

Cement based, added polymer emulsion,
contains special chemicals, two component
waterproofing product.
Very High Flexibly
Very High Adherence
It has a high level of crack bridging.
Excellent adhesion to mineral based
surfaces.
Resistant to temperature differences.

DESCRIPTION:
Cement based, added polymer emulsion,
contains special chemicals, two component
waterproofing product.
Very High Flexibly
Very High Adherence
It has a high level of crack bridging.
Excellent adhesion to mineral based
surfaces.
Resistant to temperature differences.
ADVANTAGES:
Easy and fast application
Elasticity is increased extra.
Extended working time.
Can be applied by spray equipment
High crack bridging feature.
It forms a jointless, seamless, permanent,
moisture and waterproof waterproofing
layer.
Resistant to chemicals and salt solutions in
soil.
Water vapor permeable.
Available use for moisture surfaces.
Provides high resistance to freeze-thaw
cycle.
USAGE AREAS:
Waterproofing of mineral surfaces such as
concrete, plaster, exposed concrete and
screed,
Under wet areas such as bathrooms, toilets
and kitchens on balconies and terraces,
Waterproofing of horizontal and vertical
surfaces, waterproofing positive side of the
structures, waterproofing of structures that
above the ground,
Waterproofing of retaining walls and platen
walls,
Used for waterproofing of structures above
and below ground (soil part),
Do not apply where water is observed from
the negative side

( 23 °C Temparature and 50 % for relative
humidity)
Mix Density : 1850 kg/m3
Application Temperature : +5°C +30°C
Capillary Water Absorption : ≤ 0,1
kg/(m2.min.05 )
Compressive Strenght : 7 bar Positive
Coating on: 1 day
Water test : 7 days
Final Strenght : 14 days
***These values were obtained as a result
of laboratory tests, just contain finished
applications according to drying time
performance. Due to differences in
temperature and humidity values in the
construction site, the values may change.

Surface Preparation:
The surface; must be cured, dry and
durable. Loose surface mortar and such as
residues should be cleaned and reached
durable surface.
In case of the necessity the surface should
cleaned mechanically.
Oil, grease, dirt, paint, salt and vomiting that
prevent adhesion should be removed.
If there are segregation, pits and fractures
on the surface, it should be repaired with
the structure repair mortar prepared by
mixing with DAYMAN PAIR PLUS and
DAYMAN LATEX C, the mixed mortar
should be applied at least 24 hour before.
Iron and wooden wedges on the surface are
removed and active water leakages and
gaps are formed with DAYMAN D-STOP
SPEED required.
Corners and joints should be chamfered by
DAYMAN REPAIR PLUS or D-BAND 120
AR – D-BAND ST.
Before the application the surface should be
moist.
Preparation Of The Mixture:
The liquid component is poured into an
empty and clean bucket, pour slowly the
powder component into the same water
bucket and use 400 rpm.mixer,
Do not add water to the product,
Rest 3-5 minutes to have the mortar.
Before starting the application mix 30
second again.
Application:
The surface to be applied must be wet and
waited until it becomes moist.
Ready product should be applied by brush
or spray equipment.
It should be applied as 2 -3 time on the
surface.
The application of each layer should be
perpendicular to the previous one.
Should be wait 30 until full dry between the
layers
Protective layer such as screed and ceramic
should be applied on the places which has
traffic load.
The expired mortar should be disposed
of.he surface to be applied must be wet and
waited until it becomes moist.
Ready product should be applied by roll,
brush and trowel.
It should be applied as 2 -3 time on the
surface.
The application of each layer should be
perpendicular to the previous one.
Wait at least 6 hours until full drying.
Protective layer such as screed and ceramic
should be applied on the places which has
traffic load.
Ready product must be used in 30 minutes.
The expired mortar should be disposed of.

Temperature should be between +5 °C and
+35 °C during the application.
Do not apply on surfaces that are at risk of
frost.
In addition, it should not be applied in
extremely hot, rainy or windy weather.
As it has not UV resistance it must be
covered by a cover product when it applies
open areas,
The product should protected from rain,
frost and negative out conditions till it cured,
The product becomes waterproof after 7
days in 23°C,
This time can be vary depending on the
temperature and moist ratio.
While doing ceramic covers, it advised to
use Dayman ceramic adhesive in order to
provide a complete work.

CLEANING OF INSTRUMENTS:
DAYMAN D-LASTIC SUPER 430 should be
cleaned by water when it wet.
DAYMAN D-LASTIC SUPER 430 after
become dry should be cleaned by the
mechanical ways.

CONSUME:
2,00 – 4,00 kg/m².

PACKING:
30 kg.Set
Liquid component: 10, 00 kg
Pallet Dimension:80×120
Qty.on Pallet:60
Powder component: 20, 00 kg
Pallet Dimension:80×120
Qty.on Pallet:60

COLOR:
Grey

SHELF LIFE:
1 year from the production date under
proper storage conditions.
DAYMAN D-LASTIC PLUS 430 – Liquid
Component should be stored as +5°C’nin in
case of froze under 0 °C temperature.
Used bags must be closed strictly after use.

SHELF LIFE:
1 year from the production date under
proper storage conditions.
DAYMAN D-LASTIC PLUS 430 – Liquid
Component should be stored as +5°C’nin in
case of froze under 0 °C temperature.
Used bags must be closed strictly after use.
SAFETY RECOMMENDATIONS:
Wear work clothes, protective gloves,
glasses and masks should be used during
application.
As it cement based do not breathe and do
not touch skin and eyes.
As cured materials has irritating effect, do
not touch with skin and eyes, in case of any
contact rinse with soap and plenty of water,
in case of any swallow see doctor urgently.
Food and beverage materials should not be
kept in the application area and should not
be eaten.
Store out of reach of children.
This product packaging must be disposed of
in accordance with applicable laws.
This responsibility rests with the end user of
the product.
For more information please check the
Material Safety Data Sheet.

LIMITATIONS OF LIABILITY:
The information in this technical data sheet
is given according to technical information,
experience and test result.
As GENERALTÜRK A.Ş. cannot control the
usage of the product that used under which
kind of conditions, it does not accept any
responsibility for the application result and
does not guarantee it.
The product suitability for the product user
should be tested and decided accordingly.
All products should be considered in the
advice of those technical knowledge and
equipment.
GENERAL TURK A.Ş can not accept any
resposibility that occures because of missuse,it only responsible for the written
suggestions that shows the products where
and how use.
GENERALTÜRK A.Ş. It may change the
properties of its products without
announcement.
The technical data sheet is valid until the
next time it is printed and all previous
technical data sheets invalidate the
description
Wear work clothes, protective gloves,
glasses and masks should be used during
application.
As it cement based do not breathe and do
not touch skin and eyes.
As cured materials has irritating effect, do
not touch with skin and eyes, in case of any
contact rinse with soap and plenty of water,
in case of any swallow see doctor urgently.
Food and beverage materials should not be
kept in the application area and should not
be eaten.
Store out of reach of children.
This product packaging must be disposed of
in accordance with applicable laws.
This responsibility rests with the end user of
the product.
For more information please check the
Material Safety Data Sheet.

Click to view the Technical Sheet.