Dayman Technical Build Chemicals

Phone : + 90 224 452 55 16

Email : info@dayman.com.tr

D LEVEL 750

It is a cement-based, self-leveling screed that can be applied between 2-10 mm in one
layer

Description

It is a cement-based, self-leveling screed
that can be applied between 2-10 mm in
one layer, contains hyper-plasticizing
chemical additives that provide easy
spreading.

Category

DESCRIPTION:
It is a cement-based, self-leveling screed
that can be applied between 2-10 mm in
one layer, contains hyper-plasticizing
chemical additives that provide easy
spreading.

ADVANTAGES:
Easy and fast preparation.
Can be applied by mob or trowel.
Self levelling.
Suitable for floors exposed to medium and
intensive traffic.
It can be opened to traffic after 6 hours.
It became to scale by self levelling,
It is suitable for application in 2-10 mm
thickness without shrinkage cracks.
Resistant to abrasion.
Because of the private polymer, it has high
adhesion power.

USAGE AREAS:
Hospital, shopping malls. Schools, hotels,
Exposed to medium and intensive traffic,
before the last floor cover of the all
structure.
To create a solid and smooth surface
against wear and dust,
PVC, laminated flooring, wooden, carpet,
under the ceramic covers,
It is used after cement-based surfaces after
floor insulation.

( 23 °C Temparature and 50 % for relative
humidity)
Mix Density : 2,10 kg/dm3
Application Temperature : +5 – +30 °C
Compressive Strenght : ≥ 30 N / mm²
Bending Strenght 28 days : ≥ 5 N / mm²
Adherance : 1,70 N/mm²
***These values were obtained as a result
of laboratory tests, just contain finished
applications according to drying time
performance. Due to differences in
temperature and humidity values in the
construction site, the values may change.

Surface Preparation:
The surface; must be cured, dry and
durable. Loose surface mortar and such as
residues should be cleaned and reached
durable surface.
In case of the necessity the surface should
cleaned mechanically

Oil, grease, dirt, paint, salt and vomiting that
prevent adhesion should be removed.
If there are segregation, pits and fractures
on the surface, it should be repaired with
the repair mortar prepared by mixing with
DAYMAN PAIR PLUS and DAYMAN
LATEX C, the mixed mortar should be
applied at least 24 hours before.

Preparation Of The Mixture:
5,0-5,50 lit. liquid component is poured into
an empty and clean bucket.
Pour slowly 25 kg.powder into the water
bucket and use 400 rpm.mixer,
Do not add water after,
Rest 3-4 minutes to have the mortar.
Before starting the application mix 30
second again.

Application:
The surface to be applied must be primed
with DAYMAN LEVEL PR 617 as thinning
½.
There is risk of crack if primer is not done.
Pump casting is recommended in large
areas.
The prepared mortar is poured onto the
surface and the mortar is spread
automatically.
The thickness of the self-leveling mortar
should be adjusted with a steel trowel.
Level the surface with a spiked roller to
prevent air bubbles.
Can be walked on 6-8 hours after
application.
The application of second layer should be
done after 3 days..
It is recommended that the process be
completed within 15-20 minutes in order to
maximize the benefit of the product due to
its expansion.
The expired mortar should be disposed of.

Temperature should be between +5 °C and
+35 °C during the application.
Do not apply on surfaces that are at risk of
frost.
In addition, it should not be applied in
extremely hot, rainy or windy weather.
The product should protected from rain,
frost and negative out conditions till it cured.
The time period, can be vary according to
temperature and moist conditions.

CLEANING OF INSTRUMENTS:
DAYMAN D-LEVEL 750 should be cleaned
by water when it wet.
DAYMAN D-LEVEL 750 after become dry
should be cleaned by the mechanical. ways.

CONSUME:
1, 70 kg/dm³
Max.application thickness 10 mm. in one
shot.

PACKING:
In a craft bag: 25, 00 kg
80×120 pallet dimension
54 qty.on pallet

COLOR:
Grey

SHELF LIFE:
1 year from the production date under
proper storage conditions.
Wear suitable protective clothing, protective
gloves, goggles and mask during
application

SAFETY RECOMMENDATIONS:
As it cement based, do not breath and do
not touch with skin and eyes,
Due to the irritating effects of uncured
materials, skin and eyes should not be
contacted, in case of contact with wash
plenty of water and soap, if swallowed seek
medical attention immediately.
Food and beverage materials should not be
kept in the application area and should not
be eaten.
Store out of reach of children.
This product packaging must be disposed of
in accordance with applicable laws.
Disposing responsibility is under the end
user.
For more information please check the
Material Safety Data Sheet.

LIMITATIONS OF LIABILITY:
The information in this technical data sheet
is given according to technical information,
experience and test result.
As GENERALTÜRK A.Ş. cannot control the
usage of the product that used under which
kind of conditions, it does not accept any
responsibility for the application result and
does not guarantee it.
The product suitability for the product user
should be tested and decided accordingly.
All products should be considered in the
advice of those technical knowledge and
equipment.
GENERAL TURK A.Ş can not accept any
resposibility that occures because of missuse,it only responsible for the written
suggestions that shows the products where
and how use.
GENERALTÜRK A.Ş. It may change the
properties of its products without
announcement.
The technical data sheet is valid until the
next time it is printed and all previous
technical data sheets invalidate the
description

Click to view the Technical Sheet.